Solid-State Multiplexers Reduce Half-Bridge Error

Jan. 24, 2000
The half-bridge configuration is handy when using nonlinear sensors, such as thermistors, since it can partially compensate for the sensor's nonlinearity. However, multiplexing a single resistor to multiple sensors generally requires the use of...

The half-bridge configuration is handy when using nonlinear sensors, such as thermistors, since it can partially compensate for the sensor's nonlinearity. However, multiplexing a single resistor to multiple sensors generally requires the use of mechanical relays because the switch resistance will appear in series with the system's sensor.

The circuit shown, which uses solid-state multiplexers, eradicates the effects of multiplexer on-resistance. Multiplexers MPX1 and MPX2 are configured as a double-pole switch. Op-amp U3 buffers the sensor voltage, VT, largely eliminating the effect of the resistance of MPX2. U4 then subtracts VT from the reference voltage, VREF. U1 samples the voltage across the source resistor, RS , while the high dc gain of U2 forces this voltage to be equal to (VREF ­ VT ). The resulting current through the sensor, RT, is exactly the same as in the equivalent circuit and is independent of the resistance of MPX1. The 10k resistors and 100-pF capacitors are included to stabilize the feedback loop.

In order to minimize error, the multiplexer resistance should generally be less than about half the value of RS. There are two limiting factors: the common-mode range of U1 and the output-voltage capability of U2. If the multiplexer resistance is too high compared to RS, the finite common-mode rejection of U1 may degrade the measurement accuracy.

Because a trade-off exists between on-resistance and leakage current, the lowest resistance multiplexer doesn't necessarily provide the smallest error. With the devices and values shown, 16-bit accuracy with less than 15 µs settling time can be achieved. But care must be taken to minimize the stray capacitance appearing across the sensors.

Three of the multiplexer inputs provide a ground reference, a reference resistor measurement, and an open-circuit reference. Measurement accuracy is basically independent of the accuracy and stability of RS, VREF, and the amplifier offset voltages.

See associated figure.

Sponsored Recommendations

Board-Mount DC/DC Converters in Medical Applications

March 27, 2024
AC/DC or board-mount DC/DC converters provide power for medical devices. This article explains why isolation might be needed and which safety standards apply.

Use Rugged Multiband Antennas to Solve the Mobile Connectivity Challenge

March 27, 2024
Selecting and using antennas for mobile applications requires attention to electrical, mechanical, and environmental characteristics: TE modules can help.

Out-of-the-box Cellular and Wi-Fi connectivity with AWS IoT ExpressLink

March 27, 2024
This demo shows how to enroll LTE-M and Wi-Fi evaluation boards with AWS IoT Core, set up a Connected Health Solution as well as AWS AT commands and AWS IoT ExpressLink security...

How to Quickly Leverage Bluetooth AoA and AoD for Indoor Logistics Tracking

March 27, 2024
Real-time asset tracking is an important aspect of Industry 4.0. Various technologies are available for deploying Real-Time Location.

Comments

To join the conversation, and become an exclusive member of Electronic Design, create an account today!