Designing to Achieve Medical Temperature Measurement Accuracy

Feb. 19, 2019
Sponsored by Texas Instruments: It’s hard to find a good, accurate temperature sensor, particularly when it comes to patient monitoring. However, a collaborative effort has broken through with a new wearable solution.

Download this article in PDF format.

Temperature is probably the most common physical measurement made during medical diagnosis or evaluation. Body temperature is an accurate predictor of many types of conditions and illnesses. The typical human temperature is within the range of 97.7°F to 99.5°F (36.5°C to 37.5°C) with 98.6°F (37°C) as being normal.

Such temperature readings are usually measured with a sensor under the tongue by a nurse with a portable thermometer. It takes less than 10 seconds. The precision is only one digit after the decimal point, but that’s generally enough to get an initial assessment for diagnostic purposes.

This approach isn’t good enough for clinical testing or for keeping track of human temperature over time. Therefore, some new method was required. Specifically, he need was for a temperature sensor with the 0.1°C precision of a resistance temperature detector (RTD) but without a 100-Ω platinum wire coil taped into your armpit.

A new approach offered by Texas Instruments gives the desired precision with a maximum error of less than ±0.3°C. This breakthrough development owes its success to a new wearable temperature sensor. TI and the University of California San Diego and San Francisco collaborated to improve wireless patient monitoring within the medical setting via TI's new digital temperature sensor, which offers ±0.1°C high accuracy.

 Sponsored Resources: 

The Need

Demand for precise temperature measurement is critical in clinical studies and in wearable patient-monitoring products. R&D revealed that thermistors weren’t up to the task because of the difficult calibration. Though the RTD is ideal because it provides the necessary precision, it’s out of the question due to the devices’ bulk and complexity.

Semiconductor IC temperature sensors have gradually improved over the years, and with good design and packaging can meet the need. The gold standard for patient-monitoring thermometer accuracy is the American Society for Testing and Materials (ASTM) E1112. Another similar standard is ISO-80601-2-56.

Designing for Minimum Error

It was determined that for any temperature sensor to meet the required accuracy and precision, it must meet these requirements:

  • The sensor must always remain in good thermal contact with the patient’s skin.
  • The sensor must be thoroughly thermally isolated from all other heat sources.
  • The sensor must use minimal power so that self-heating effects are negligible.

The sensor emerging from this development work is Texas Instruments’ TMP117 temperature sensor. It’s contained within a very thin small outline, no-lead, 2- × 2-mm WSON package (Fig. 1). This type of sensor measures the temperature of the silicon die. It’s designed to be used as a skin patch taped into place on the inside of wearer’s forearm.

1. This is the basic structure of the precision temperature sensor in a WSON package. Note the flexible gold base that makes good contact with the patient’s skin.

The sensor uses a thin gold base that’s flexible as well as biocompatible in order to make excellent thermal contact with the skin. Thin flexible batteries are now available to power this sensor—it will work with any voltage from 1.8 to 5.5 V. Average current draw is 3.5 µA. The recommended wireless standard is Bluetooth Low Energy, although any RF technology will work.

Summarizing the TMP117

Figure 2 shows a block diagram of the sensor. Note that the basic temperature sensor is a BJT connected as a diode. Its output is conditioned and sent to a 16-bit ADC. Least-significant-bit (LSB) resolution is 0.0078°C. The analog-to-digital converter (ADC) operates at a 1-Hz conversion cycle.

2. The TI TMP117 temperature sensor’s ADC has 16-bit resolution and the serial I/O is SMBus- or I2C-compatible.

Other features include digital offset for system correction, selectable averaging, temperature alerts, and a general purpose 48-bit EEPROM. The output is via a serial interface that’s compatible with either SMBus or I2C.

Other Applications

The TMP117 is so good it can be used in other applications. For example, it can replace PT100, PT500, and PT1000 RTDs in industrial applications. It’s also usable in environmental monitoring and thermostats. Other uses include wearables, asset tracking and cold chain, gas meters, and test and measurement equipment.

 Sponsored Resources: 

Sponsored Recommendations

Understanding Thermal Challenges in EV Charging Applications

March 28, 2024
As EVs emerge as the dominant mode of transportation, factors such as battery range and quicker charging rates will play pivotal roles in the global economy.

Board-Mount DC/DC Converters in Medical Applications

March 27, 2024
AC/DC or board-mount DC/DC converters provide power for medical devices. This article explains why isolation might be needed and which safety standards apply.

Use Rugged Multiband Antennas to Solve the Mobile Connectivity Challenge

March 27, 2024
Selecting and using antennas for mobile applications requires attention to electrical, mechanical, and environmental characteristics: TE modules can help.

Out-of-the-box Cellular and Wi-Fi connectivity with AWS IoT ExpressLink

March 27, 2024
This demo shows how to enroll LTE-M and Wi-Fi evaluation boards with AWS IoT Core, set up a Connected Health Solution as well as AWS AT commands and AWS IoT ExpressLink security...

Comments

To join the conversation, and become an exclusive member of Electronic Design, create an account today!