Limitations Promo
Limitations Promo
Limitations Promo
Limitations Promo
Limitations Promo

Upper-End Limitations of a Duty Cycle

April 21, 2020
This design tip illustrates how utilization of a P-channel MOSFET is likely the best option to cost-effectively deliver 100% duty-cycle capabilities in a switching regulator.

Switching regulators use a duty cycle to realize voltage or current feedback control. The duty cycle is the ratio of the turn-on time (TON) to the complete cycle length, the turn-off time (TOFF) plus on time, and defines a simple relationship between the input voltage and an output voltage. Other factors may be considered for a more exact calculation, but theyre not decisive in the following explanations.

The duty cycle of a switching regulator depends on the respective switching-regulator topology. A step-down (buck) converter (Fig. 1) has a duty cycle D according to D = output voltage/input voltage. For a step-up (boost) converter, the duty cycle D = 1 (input voltage/output voltage).

These relationships apply to continuous conduction mode (CCM). Here, the inductor current doesn’t drop to 0 in a time period, T. This mode is frequently found in circuits with operation at rated load. At lower loads or for intentional intermittent operation, the coil current discharges during the off time. This mode is called discontinuous conduction mode (DCM). These two modes of operation each have their own relationships for the respective duty cycle of a specific input voltage and output voltage.

Figure 2 shows an example of switching behavior in the time domain. Here we consider a step-down switching regulator in nonintermittent operation mode; that is, in CCM. The duty cycle is independent of the switching frequency. The period T typically lies between 20 µs (50 kHz) and 330 ns (3 MHz). If the values for input voltage and output voltage are the same, a duty cycle of 1 is needed. This means that theres only an on time and no off time. However, this isn’t possible with every switching regulator.

In Figure 1, the high-side MOSFET would have to be continuously on for this to occur. If this switch is designed as an N-channel MOSFET, it needs a higher voltage at the gate than the input voltage of the circuit in order to operate. If there’s a certain off time after each on time, as is the case for a duty cycle of < 1, a higher voltage than the supply voltage can be generated quite easily according to the charge-pump principle. This isn’t possible with a duty cycle of 100%, though.

Thus, for switching regulators with 100% duty-cycle capabilities, either elaborate charge pumps acting independently of the switching-regulator MOSFETs must be implemented or the high-side switch shown in Figure 1 must be designed as a P-channel MOSFET. Both options result in additional effort and cost.

Figure 3 shows a switching regulator, the ADP2370 from Analog Devices, that permits a 100% duty cycle through use of a P-channel MOSFET as the high-side switch. For this type of buck converter, the input voltage can drop to very near the output voltage. With the P-channel switch integrated into the switching regulator, additional cost is avoided.

If an application requires that the input voltage be able to drop to a level very close to the output-voltage setpoint, a switching regulator that permits a duty cycle of 1, or 100%, should be selected.

Apart from this limitation on the duty cycle, determined by the high-side switch of a switching regulator topology, other limitations are imposed on the duty cycle. We will consider them in a later power-management tip.

Frederik Dostal is a Field Applications Engineer at Analog Devices.

Sponsored Recommendations

Understanding Thermal Challenges in EV Charging Applications

March 28, 2024
As EVs emerge as the dominant mode of transportation, factors such as battery range and quicker charging rates will play pivotal roles in the global economy.

Board-Mount DC/DC Converters in Medical Applications

March 27, 2024
AC/DC or board-mount DC/DC converters provide power for medical devices. This article explains why isolation might be needed and which safety standards apply.

Use Rugged Multiband Antennas to Solve the Mobile Connectivity Challenge

March 27, 2024
Selecting and using antennas for mobile applications requires attention to electrical, mechanical, and environmental characteristics: TE modules can help.

Out-of-the-box Cellular and Wi-Fi connectivity with AWS IoT ExpressLink

March 27, 2024
This demo shows how to enroll LTE-M and Wi-Fi evaluation boards with AWS IoT Core, set up a Connected Health Solution as well as AWS AT commands and AWS IoT ExpressLink security...