Power Meter Yields Magnetic Characteristics of Transformer Cores and Coil Materials

March 1, 2001
Precision power meter measures core's magnetic characteristics and power loss.

An effective transformer design requires a determination of the peak values of the magnetic flux, the magnetic field strength, and the permeability of a core at low and high frequencies. These measurements involve sinusoidal field strength or flux, but this leads to expensive and complicated signal sources. The point of interest is especially the saturation range, where there is a high demand on the signal source. A more elegant and cost-saving approach is to use “intelligent” measuring equipment with better mathematical formulas that allow arbitrary waveforms of the voltage and current. This allows the use of low-cost power sources. You can even use line voltage with a high harmonic content.

Ferrite core dissipation is directly proportional to the area of the hysteresis loop; therefore it's a function of the temperature, frequency, flux density, ferrite material, and the core's form. By supplying an arbitrary signal at the primary side of a wrapped core and the measurement of the open-circuit voltage at the secondary side, you can recognize the measurement of the dissipation. The primary peak current (Ipk) is proportional to the magnetic field strength (Hpk), and the rectification value of the open-circuit voltage (Urect) on the secondary side is proportional to the magnetic flux density. Integration of the hysteresis loop provides the equivalent to the measured true power.

The total dissipation of a wrapped core consists of a Ploss of the hysteresis, a Ploss of the eddy current, a Ploss of the winding and a Ploss of the rest. When measuring the ferrite core dissipation, you should not measure the copper losses.

In this case, the loss power is: Ploss=Utrms×Itrms×cos φ. Using the measurement circuit in Fig. 1, the voltage drop of the copper resistance at the primary circuit has no effect, because you only measure the current in the primary circuit. To measure the real magnetizing voltage, the secondary circuit runs current-less. Primary and secondary copper losses are not included in the measured loss power.

Because of the precise measurement of Utrms, Itrms, and cos φ, the integration and dynamic run through of the hysteresis loop is not necessary. A power measurement system may measure, display, and read directly in real time the dissipation. You can accomplish this by considering the computation of error of the dissipation is:

The total error of the dissipation contains an amplitude error of the measured voltage and current with a delay time difference error between these signals. The different delay times in each measuring path causes the delay time difference. Normally, the losses are very small and the phase shift nearly 90°, and so the cos φ is nearly zero. The division of Δcos φ by cos φ will result in a very high value.

Numeric Example

At a measurement of the dissipation of a ferrite core cos φ is 0.06, the primary current is sinusoidal with a frequency of f=50 kHz. With the following formula:

a time delay of only 3.8 nsec leads to an error of:

This means it's the delay time on a measurement lead shorter than 1 m. Also consider the amplitude errors:

For this measurement problem, the selection of the measuring instruments is important. An instrument measuring high amplitude accuracy isn't necessary, but you should select a meter with high power measurement accuracy. Also, a carefully wired measurement circuit is important for a high accuracy of the measured values. The measurement leads should be short and equal in length. The LMG95 is an instrument that satisfies these requirements with a special delay time adjustment that provides a delay time difference between U and I channel, typically <4nsec (see Photo on page 74).

The LMG95 power meter accesses other magnetic characteristic values, such as determination of the magnetic field strength. The peak value of the magnetic field strength is Hpk. From the first Maxwell equation:

follows with the secondary factor: quasi-stationary fields

Hpk=Peak value of the magnetic field strength in the core
n1=Primary windings
Ipk=Peak value of the primary current
lmagn=Magnetic path length

Hpk is exactly determined, independent of the signal curve form of the primary current. The only requirement is that the current must be symmetrical, so Ipk=Ipp/2.

The equation in the notation of the formula editor in the LMG95: Hpk=Ipp/2×n1/lmagn (5)

Magnetic Flux Density

The peak value of the magnetic flux density (Bpk) from the second Maxwell equation:

It follows with the secondary factor (3) and reception of equally distributed flux density in the core material:

n2=Secondary windings
A=Effective magnetic cross section of the core material
u(t)=Induced voltage at the secondary winding in time domain

B(t) is minimal/maximal with dB(t)/dt=0, which is at the zero crossings of the induced voltage. The integration between two zero crossings of the induced voltage delivers the peak value of the magnetic flux density:

Bpp=Peak-peak value of the magnetic flux density in the ferrite core
t0=Beginning of a cycle of the induced voltage
t1=Moment of the zero crossing of the induced voltage in the same cycle.

Because the induced voltage contains no direct voltage part (Udc=0), it follows that:

T=Cycle time of the induced voltage With Equation (9) it follows that:

This integral is also included in the formula of the rectified (secondary) voltage Urect:

With the LMG95 you have access to the value of the rectified voltage, so you calculate the flux density:

f=1/T, the signal frequency of the induced voltage

Bpk is also exactly determined, independent of the signal curve form. The equation in the notation of the formula editor in the LMG95 is:

Bpk=Urect/(4×f×n2×A) (13)

Relative Amplitude Permeability

Using the already calculated peak values, magnetic flux and magnetic field strength, the relative amplitude permeability is:

In the notation of the LMG95:

ua=Bpk/Hpk/1.2566 e-6 (15)

The power meter connects to the power source and the unit under test according to Fig 1, on page 75. After programming the equations in the formula editor (Fig. 2, on page 75) the calculated values can be read out in real time (Fig. 3, on page 76), plotted graphically (Fig. 4, on page 76), or printed out.

Magnetic values Hpk, Bpk, and ua that can't be measured directly are shown in real time on the display in Figs. 2, 3, and 4.

With the direct measured values: the rectified value of the induced voltage, the frequency, the peak value of the primary current, and the user supplied geometrical values of the ferrit core, it's possible to determine the magnetic flux, magnetic field strength, and the relative amplitude permeability of the ferrite core. These values can be evaluated in real time with LMG95 and displayed together with the directly-measured power loss.

References

1. Küpfmüller, K.: Einführung in die theoretische Elektrotechnik. 13. Aufl., Berlin/Heidelberg: Springer 1990.

For more information on this article, CIRCLE 336 on Reader Service Card