Single-Stage Isolated Bridgeless PFC Converter Achieves Over 98% Efficiency, 0.999 Power Factor

Oct. 1, 2010
Until now, it was considered impossible to have an AC-DC converter with PFC and isolation features provided in a single power processing stage and without

Find a downloadable version of this story in pdf format at the end of the story.

Until now, it was considered impossible to have an AC-DC converter with PFC and isolation features provided in a single power processing stage and without mandatory full-bridge rectifier. This is not the case anymore. The high performance of the non-isolated Bridgeless PFC converter (described in July 2010 Power Electronics Technology) with 0.999 Power Factor and 1.7%THD harmonic distortion is preserved with the only addition being an appropriately inserted isolation transformer. An Integrated Magnetics extension results in a single magnetic component, 3-switch configuration, compared to 14-switches and four magnetic components of the conventional Three-stage approach. As a result, this Single-stage solution has much improved efficiency of over 98%, compared to 90% of the Three-stage approach and offers simultaneously significant size and cost reductions.

The first limitation is found in the conventional Boost PFC converter shown in Fig. 1a, which can operate only from the rectified ac line as illustrated by the waveforms in Fig. 1b, thus resulting in two-stage power processing. An additional problem is that there is no simple and effective way to introduce the isolation in the conventional Boost converter of Fig. 1a.

As seen in Fig. 2a, one approach is to use a full-bridge extension of the Boost converter to introduce isolation, which is then controlled as PFC converter. Note, however, its complexity consisting of four transistors on the primary side and four diode rectifiers on the secondary side operating at the switching frequency of, for example, 100kHz with additional four diodes of input bridge rectifier operating at the line frequency of 50Hz or 60Hz resulting in total 12 switches. The line current will then have the superimposed input inductor ripple current at high switching frequency, which needs to be filtered out by an additional high frequency filter on ac line. The presence of 12 switches and their operation in the hard-switching mode results in high conduction and switching losses. The best efficiency reported with this two-stage approach is 87%, which also included additional switching devices to achieve resonant transitions and reduce switching losses.

This configuration has the start-up problem occurring due to step-up only DC voltage gain. Thus, additional circuitry is needed to pre-charge the output capacitor before start up of the converter. This problem does not exist in the Isolated Bridgeless PFC converter as described in later sections.

The most common approach for 1 kW or higher power, however, is to use a Three-stage power processing illustrated in Fig. 3a, in which the Bridge Rectifier on input is followed by the isolated full-bridge Boost PFC converter. In this case, a total of fourteen (14) switches is needed! The highest efficiency is up to 90%, so it is better then the two-stage approach. Therefore, this three-stage approach is utilized in practically all present applications for high power.

For medium and low power, an alternative approach with reduced number of switches is shown in Fig. 3b, in which the forward converter was used for the isolation stage. While the number of switches is reduced to ten, the problem is that four switching devices in the forward converter are still exposed to much increased voltage stresses on both primary side switches and secondary side switches when compared to the two-stage full-bridge solution. Note also that four magnetic pieces must be used as in full-bridge solution, when a input filter inductor is included.

NEW ISOLATED BRIDGELESS PFC CONVERTER

Clearly, the present AC-to-DC solutions with PFC and isolation use a configuration with three cascaded converters (bridge rectifier followed by two DC/DC converters) so that total power is processed in sequence three times, resulting in high power losses and low overall efficiency.

The Bridgeless PFC converter in Fig. 4a and its duty ratio modulation control of Fig. 4b were shown in July's Power Electronics Technology to operate directly from the ac line and without the need for the Full-Bridge rectifier in front. This converter has only three switches and operates on the basis of the new hybrid- switching method. Despite the use of a resonant inductor and a resonant capacitor, this hybrid switching method results in the DC voltage gain being dependent on the duty ratio only and having the same DC voltage gain as the ordinary boost converter for either positive input voltage or negative input voltage, hence providing an automatic ac line rectification without the need for a front-end bridge rectifier.

Continue on next page

The clear objective now becomes to introduce the isolation to the Bridgeless PFC converter in the simplest and most efficient way. The desired way would be not to increase the number of switches (as it was needed for ordinary boost converter!) and to obtain the simple and efficient isolation transformer. Both objectives are achieved by following a simple procedure outlined in the sequence of equivalent circuit transformations illustrated in Figs. 5a, 5b and 5c. Note that in these equivalent circuits the input voltage is designated as a positive DC source Vg in order to simplify the designation of respective components in steady-state conditions. The actual ac-dc converter is powered by the time varying ac source Vg(t).

First, the resonant capacitor is split into two resonant capacitors Cr1 and Cr2 connected in series as illustrated in Fig. 5a. Then, an inductor with magnetizing inductance, Lm is connected from their common connection point A to ground G as illustrated in Fig. 5b. Since now there are two capacitors, each one will settle on its own DC voltages V1 and V2 respectively. We can find these voltages using the State-Space Averaging, or volt-second balance on the two inductors L and Lm. However, a faster way is to use some circuit shortcuts. For example, the loop consisting of input source, two inductors L and Lm and resonant capacitor Cr1 must satisfy the requirement that the summation of DC voltages around the loop must be equal to zero. However, since neither inductor can support net average voltage across it, their DC voltage contributions are zero resulting that resonant capacitors Cr1 voltage V1 must be equal to input source voltage Vg and of the polarity as shown in Fig. 5b. On the other hand, during the ON-time interval, the two resonant capacitors are placed in parallel across the magnetizing inductance Lm, which imposes that the DC voltage V2 of resonant capacitor Cr2 must be equal to voltage V1, or:

V1 = V2 = Vg (1)

Now one can calculate the voltage across the magnetizing inductance Lm during the OFF-time interval as:

Vm (OFF-time) = V - Vg = D/ (1-D) Vg (2)

Since output DC voltage was not changed by the above equivalent circuit transformations and is equal to:

V= Vg / (1-D). (3)

This proves that the magnetizing inductance Lm is automatically volt-second balanced for any operating duty ratio D. Therefore, one can replace this magnetizing inductance with a 1:1 turns ratio two winding transformer as illustrated in Fig. 5c.

The actual time domain voltage waveforms on the two resonant capacitors are shown in Fig. 6a and Fig. 6b to have the same DC voltage Vg but superimposed on that DC voltage are the two ripple voltages which are out of phase, since during the OFF-time interval first resonant capacitor Cr1 is charging while the second resonant capacitor Cr2 is discharging and opposite taking place during the ON-time interval. Therefore, the resulting net ripple voltage across the series capacitors is equal to twice the ripple voltage on each capacitor and has no net DC voltage as shown by the waveform in Fig. 6c.

Note also that during the ON-time interval, the equivalent circuit as shown in Fig. 7a is obtained. As the magnetizing inductance Lm is large, and its impedance is very large so, to the first order, this impedance is not loading the circuit in Fig. 7a and can be removed from it to result in the resonant circuit model as in Fig. 7b in which the equivalent resonant capacitor Cr can be calculated from:

1/Cr = 1/ Cr1 + 1/ Cr2 (4)

Therefore, the same resonant current waveforms as previously obtained for the non-isolated converter of Fig. 4a and respective analytical results apply directly to the isolated converter.

Continue on next page

Note that the above analysis proceeds in the same way for the negative input voltage. Even though the steady-state conditions on the two resonant capacitors Cr1 and Cr2 will now appropriately change including the voltage polarity on them, the same output DC voltage gain given by (3) will remain. Therefore, the goal stated at the very beginning of inserting the isolation transformer into the non-isolated converter structure with minimum disturbance so that its original operation can be maintained is achieved: the isolated configuration has the same three-switch configuration, with a single controlling switch on the primary now, and two passive diode switches on the secondary side.

Now one can scale the transformer turns ratio from 1:1 to transformer with primary Np turns and secondary Ns turns as shown in Fig. 8a and result in overall DC voltage ratio of

V/ Vg = NS / NP 1/ (1-D) (5)

In addition to isolation, this gives an added flexibility so that the output voltage can be via turns ratio scaled down to any desired output DC voltage.

Note that the Bridgeless PFC IC Controller is now on the primary side of the converter as illustrated in Fig. 8a, which will result in the line current waveform as shown in Fig. 8b which has a high frequency input inductor ripple (at the switching frequency of 50kHz for example) superimposed on the low frequency (50Hz) line current. The high switching frequency ripple current is then filtered out by use of a separate high frequency filter on the converter input.

ISOLATION TRANSFORMER ADVANTAGES

The procedure followed to introduce the isolation transformer described above also highlights some of the key advantages of this transformer compared to isolation transformer in conventional isolated converters such as, for example, the forward converter and the flyback converter, as illustrated by the B-H loop curve of their respective transformers shown in Fig. 9.

First, the isolation transformer of the forward converter uses only one half of the available B-H loop as the transformer flux is set in one direction by the input switch and input voltage source, but also requires a reset mechanism to return the flux to original zero AC flux position. The reset mechanism involves either a third reset winding or more commonly used a flyback type reset, known as a voltage clamp reset in forward converter.

The isolation transformer in flyback converter also uses only one half of the core flux capability as forward converter. However, it has an additional drawback that its transformer during ON-time stores all the input energy and during OFF-time releases stored energy to the load. Therefore, the flyback-type transformer must use a large air-gap to store that energy resulting in much reduced magnetizing inductance as illustrated by the reduced slope of the B-H loop. The larger the dc load current the smaller is this slope. The ac flux is then superimposed on top of this large dc bias, leaving only a remaining available flux density for the AC flux.

The isolation transformer in the Isolated Bridgeless PFC converter utilizes both parts of the available core flux capability as illustrated in Fig. 9. In addition there is no need for third reset winding or voltage clamp type of reset as in forward converter as the transformer is automatically volt-second balanced for any duty ratio D. In addition, this transformer operates as a true ac transformer as it does not store DC energy and can therefore be built on an un-gapped magnetic core resulting in large magnetizing inductance and small magnetizing current. The fact that this isolation transformer does not store any DC energy like a flyback converter can be easily verified on the converter itself: the primary winding has in series with it a primary side resonant capacitor Cr1 which must be charge balanced and the same holds true for the secondary side resonant capacitor Cr2. Therefore, neither primary nor secondary winding can have a net DC current, so the transformer itself does not store any energy.

These isolation transformer advantages clearly translate into a much smaller size and higher efficiency of the transformer, which has bi-directional flux capability with no DC energy storage.

Continue on next page

The converter of Fig. 8a has two magnetic pieces: the input inductor and the isolation transformer requiring two magnetic cores. However, the converter topology of Fig. 8a has a unique property: both inductor L and transformer primary tout have the identical square-wave excitation voltages vL1 and Vp for any operating duty ratio D as illustrated in Fig. 10a. In the loop consisting of primary winding of the isolation transformer and input voltage source, the ac model is obtained by shorting the input voltage source and primary resonant capacitor resulting in the inductor winding and transformer primary winding being in parallel across each other. Therefore, regardless of the ac voltage excitations, both inductor and transformer have identical ac waveforms which makes it possible to place them on the common core, as shown in Fig. 10b, thus eliminating one magnetic core. Furthermore, the proper placement of the air-gap on the common core, such as on the side of the transformer (Fig. 10b) shifts all the ripple current from the inductor winding into transformer winding, resulting in zero ripple current of the input inductor current as illustrated with full line in Fig. 10c. Thus, the converter could even operate on the boundary of the Discontinuous Inductor Current Mode (DICM) as shown by the dotted line current waveforms in Fig. 10c, and still result in a very small near zero input inductor ripple current.

Clearly, such a large inductor ripple current would require a substantial separate high frequency filter in the conventional three-stage approach. Here it comes literally with no penalty, but in fact with additional size and performance advantages. For example, such large allowed input inductor ripple current could be used to reduce the size of the Integrated Magnetics core. Furthermore, operation at the edge of DICM was shown in the past to result in low total harmonic distortion for line frequency of 400Hz. Such Integrated Magnetic implementation is shown in Fig. 11a and respective clean ac line free of high frequency harmonics in Fig. 11b.

The current direction in the resonant inductor is changing from one direction in OFF-time interval to another direction in ON-time interval. This change of the direction of inductor current during the short transition could cause the voltage spikes on the switch S. The faster the change, the bigger the voltage spike would be. However, due to small energy stored in this small inductor, this spike can be effectively suppressed by use of a Zener diode, which would limit the voltage spike and dissipate its energy. Since the converter operates for both polarities of the input voltage, the bi-directional Zener diode, called Transorber, is used in practical application. This, once again, would dissipate all of the voltage spike energy and limit the spike voltage. However, a number of non-dissipative ways also can be employed to recover most of the energy contained and deliver it to the load, thus increasing the efficiency and reducing switch stresses during the transition.

IMPLEMENTING CONTROLLABLE SWITCH S

As shown before for the nonisolated Bridgeless PFC converter (July Power Electronics Technology), the same implementations for switch S equally applies for this Isolated Bridgeless PFC converter: two RBIGBTs in converter of Fig. 12a and two n-channel MOSFETs in converter of Fig. 16a.

It is expected that a single two-quadrant switch having the characteristics of Fig. 12b will be available soon. As the conduction losses are by far the dominant losses of the Isolated Bridgeless PFC Converter, such two-quadrant switch implementation would raise the overall efficiency from the current 97% to over 98%.

The low voltage stresses of the switches in the Isolated Bridgeless PFC Converter of Fig. 13a are shown in Fig. 13b for primary switch S and in Fig. 13c for secondary side rectifiers Cr1 and Cr2. The secondary side current rectifiers have the voltage stresses equal to the output DC voltage and therefore result in minimum voltage stress. The voltage stress of the input switch S is also low since it is equal to the output voltage reflected by the turn's ratio of the transformer. Low voltage stresses lead to higher efficiency and converter cost reduction.

The DC gain characteristic of Isolated Bridgeless PFC Converter of (5) suggests the start-up problem for the same reason as the other isolated boost converters, such as one in Fig. 2a having the same boost type gain characteristic (5). This converter, however, does not have such a start-up problem due to its special mode of operation at low duty ratios, which permit a soft-start from zero output voltage.

Continue on next page

Shown in Fig. 14 with dashed line is the ideal dc voltage gain characteristic given by Equation (5) for the special case of 1:1 isolation transformer, which was used in experimental verification. Just as in the non-isolated Bridgeless PFC Converter, the actual measured dc voltage gain shown in solid line reveals the existence of the shaded region at very low duty ratios during which the dc conversion gain drops to zero. Therefore, effectively, the actual measured dc voltage gain is that of a step-down/step-up type. Thus, the output dc voltage can be started smoothly from zero dc output voltage and brought by duty ratio increase into a step-up dc conversion region, without the need for separate start-up circuitry to precharge the output capacitor to the DC voltage gain of one as would be otherwise needed.

The insertion of the isolation transformer demonstrated that the original topological structure and PFC performance of the Bridgeless PFC converter (nonisolated) is preserved in the isolated extension including retaining the same switches. Therefore, the original converter prototype of 400W of the Bridgeless PFC converter (August Power Electronics Technology) was modified by inserting a 1:1 isolation transformer. As expected, the power factor (PF) and Total Harmonic Distortion (THD) measurements remain the same at 0.999 PF and 1.7%THD for 60Hz, 110V line operation.

However, the efficiency was reduced by the losses in the added isolation transformer, resulting in an added power loss of 0.25% to 0.5% depending on the size of the transformer.

Besides the large number of switches it requires, the conventional Three-stage conversion also results in large voltage stresses on some of the switches, as it uses an intermediate 400V high voltage DC bus. The conceptual diagram shown in Fig. 15a indicates these three conversion stages and the conversion step-up to intermediate 400V high DC voltage bus.

The single-stage conversion of the Isolated Bridgeless PFC Converter eliminates the intermediate high DC voltage bus goes directly from the AC line through built-in rectification and PFC conversion to isolated lower voltages such as 48V used in telecommunication shown Fig. 15b.

The comparison of the key performance characteristics of the Single-stage Isolated Bridgeless PFC converter with the conventional Three-stage approach using the Bridge Rectifier, Boost PFC converter and Isolated Full-Bridge Converter is shown in the table.

Note in particular the dramatic reduction of the number of switches from 14 to 3 and simultaneous efficiency improvement from 90% to over 97% with the magnetic components reduction from 4 to 1 and corresponding large reduction in weight, size and cost.

Hybrid switching has made possible the use of Single-stage approach and isolation transformer insertion with minimum change from the operation of the non-isolated version.

Several applications of the Isolated Bridgeless PFC Converter confirm the converter's versatility for a wide power range from 75W to several kilowatts.

BUILT-IN ADAPTER FOR LAPTOP COMPUTERS

Past attempts to put AC Adapters inside laptop computers have failed for two reasons:

  1. Low efficiency below 90% causes too much dissipation, even at 75W.

  2. Large size due to many magnetic pieces, which do not fit within the low profile of laptop computers.

Both of these problems are now resolved with the Isolated Bridgeless PFC converter, which can be designed to provide for example, 100W laptop AC adapter generating 18V to 20V DC output and charging the laptop battery directly from the ac line while providing unity power factor and low distortion.

Continue on next page

Furthermore, a single Integrated Magnetic piece can be made using the flat magnetic core, thus meeting the low profile requirements of even most demanding current laptop computers with the low profile of less than one inch. Finally, to increase efficiency, the output diode rectifiers can be implemented with two synchronous rectifier MOSFETs and high-side drivers, such as illustrated in Fig. 16a. To further reduce size and cost, two MOSFETs and high side drivers could be replaced by a single integrated silicon solution, such as Dr MOS, available from a number of semiconductor vendors.

BATTERY CHARGER FOR HYBRID CARS AND ELECTRIC BICYCLES

Another attractive application is a battery charger for hybrid and electric cars (Fig. 16b), which is used to charge 200V Lithium Ion batteries used in most hybrid cars. Clearly, the high efficiency will result in increased miles traveled per cost of charge.

Electric bicycles are becoming more popular worldwide, especially in Japan and Europe. At present, there are no portable chargers for bicycles due to their current large size. The new Isolated Bridgeless PFC converter can be used for 120W portable chargers for bicycles and eliminate the need for big, bulky and costly home charger.

Finally, for industrial applications, more efficient, smaller, and less expensive battery chargers for forklift trucks, golf carts, and wheelchairs will be available.

TELECOMMUNICATIONS POWER SUPPLY

As the telecommunications power has standardized on 48V battery as a back-up source for its reliable operation, the Isolated Bridgeless PFC converter fits into that application as well as it can provide a low-cost and efficient rectifier for the 3kW and 10kW needed in those applications.

The new Hybrid Switching method has enabled the Single-stage Isolated Bridgeless PFC Converter, which consists of only three switches and one magnetic component, to effectively replace a Three-stage approach with up to 14 switches and 4 magnetic components. The resultant large reduction of losses and simultaneous reduction of size, weight, and cost, suits this approach to a host of consumer and industrial applications.

THIRD “IMPOSSIBLE” CONVERTER SOLUTION

The third in a series of “impossible” converter solutions, the “Isolated Bridgeless PFC Converter with Pulsating Input Current” (patents pending), is shown in Fig. 17. The converter has a transformer with flyback-type characteristics, yet its output DC voltage is positive (not negative as in flyback converter) and its DC voltage gain characteristic is of the boost type, that is 1/(1-D).

Footnote: Isolated Bridgeless PFC Converter™ and Single-stage Isolated PFC Converter™ are trademarks of TESLAco.

Editorial Note: For questions regarding this article and for contact information to the author the readers are directed to TESLAco's Web site www.teslaco.com.

REFERENCES

  1. Slobodan Cuk, “Modelling, Analysis and Design of Switching Converters”, PhD thesis, November 1976, California Institute of Technology, Pasadena, California, USA.

  2. Slobodan Cuk, R.D. Middlebrook, “Advances in Switched-Mode Power Conversion, ” Vol. 1, II, and III, TESLAco 1981 and 1983.

TABLE

Table: Comparison of the Single-stage solution of Isolated Bridgeless PFC converter with a Three-stage approach of Bridge rectifier, Boost PFC converter and an Isolated Full-Bridge Converter. POWER PROCESSING SINGLE-STAGE THREE-STAGE Type of Converter ISOLATED BRIDGELESS PFC BRIDGE-BOOST PFC-FULL-BRIDGE Switching Method HYBRID Square-wave Number of switches 3 14 Transistors 1 5 Switch-voltage Stress Low High Lossless-switching YES NO Control Simple Complex Magnetics pieces 1 4 Power Losses 2% 10% Efficiency >98% 88% to 90% Size Small Big Weight Light Heavy Cost Low High

Download the story in pdf format here.