Last month's “Analog Feedback” department discussed some of trends and technical issues shaping the development of DIN Rail power supplies. That article described some of the general specifications and features associated with these products. In this edition of “Analog Feedback,” we examine how these development trends are reflected in a sampling of recently developed models.
The table lists some of the key specifications and features for these models. Not included in this list are the various agency approvals.
Company/Model | Output Voltage (V) | Output Power (W) | Output Current (A) | Special Features |
---|
ABB Entrelec CP Range | 5 to 48 | — | 300 mA to 20 A | *Touchproof connection terminals; *most CP types accept 90 to 260 Vac, 47 to 440 Hz input with no adjustment; *supply with 105 to 260 Vdc is possible with nearly all CP types |
Astec Power ADN Series | 24 | 60 to 480 (Full power to 60°C w/out forced-air) | 2.5 to 20 | *50% brownout tolerance from nom. input; *90%efficiency; *power factor correction; *auto select between 115 and 230 Vac inputs; *85-264Vac universal input on 60-W version |
Astrodyne DRP480 Series | 24 or 48 | up to 480 (Full power to 55***C w/out forced air) | — | *Integral input EMI/Class B filter; *8.9 in. × 4.9 in. × 4.9 in. package; *active power factor correction to 0.98; *integral power-good LED indicator |
Lambda DLP Series | 24 | 180 | 7.5 | *Lead-free packaging; *maximum efficiency is 87%; *common height and depth of 3.8 in × 4.3 in; power factor correction and universal 85 to 265 Vac input on 180-W and 240-W units |
Phoenix Contact QUINT G2 | 24 nom. (22.5 to 28.5 V adjustment) 12 and 48 also available | — | 2.5, 5, 10, 20, 30 and 40 | *Integral function monitoring via dual alarm outputs with LED indication; *screw actuated terminal of wiring; *isolated relay relay contact and an active blocks transistor blocks switching output for preventive function monitoring. |
Schneider Electric Phase0 dc power supplies | 24 nom. (21.6 to 26.4 adjustment) | — | 0.3, 0.6, 1.2 | *100-240 Vac or 110-220 Vdc input range; *overload, short-circuit and overvoltage protection; *output voltage stability of +2% max; *terminals accept stranded or solid wire and wires with forked or ring tongued connects. |
Sola/Hevi-Duty SDP06-24-100T | 24 nom. (22 to 28 adjustment) | 15 | — | *0.9 in. width; *handles output current at double the nominal for <2 s at 60???C; *universal input. | XPiQ THF series | 12 to 48 nom. (±10% adjustment) | 45 to 240 | | *Universal ac inputs except for 120-W model with switched input; *up to 85% efficient; *overvoltage, overcurrent and overtemperature protection. |
*A list of vendor Web sites appears in the last month's Analog Feedback section. |