Telephone Line-Feed Detector Meets FCC Regulations

April 14, 2005
According to FCC regulations, a telephone line in the on-hook state must not be dc loaded by less than 5 MV of resistance up to 100 V. Also, it must be galvanically isolated from the local ground. In the case of a standard dc line-feed of 48 V, this m

According to FCC regulations, a telephone line in the on-hook state must not be dc loaded by less than 5 MV of resistance up to 100 V. Also, it must be galvanically isolated from the local ground. In the case of a standard dc line-feed of 48 V, this means that the dc load must be less then 10 µA. Furthermore, the tip and ring must be isolated by a transformer in case the telephone circuit must be locally ground referenced.

The figure shows one way to detect the presence of the dc line-feed in both the off- and on-hook states while meeting the FCC regulations. A transformer-transfer impedance change is used for this purpose. If there's no dc on the line between tip and ring, then the n-channel FET Q1 shorts transformer T1's secondary. This loads the primary so the ac at the primary, generated by U1A, is minimal. Also, Q2 doesn't conduct and the #DETECT line is high, at +5 V.

If there's a dc voltage higher than about 10 V on the line, Q1 doesn't conduct, the transformer secondary is open, and there are a couple of volts of ac on the primary of the transformer. Then Q2 conducts, and the #DETECT line goes low.

The frequency of the Wien-bridge tone generator formed by U1A is about 20 kHz. The R4-C2 time constant is adjusted for this frequency, so the #DETECT line stays within CMOS/TTL logic high/low limits. D2, D3, and R10 reduce the gain at higher amplitudes. Therefore, the waveform at the output, pin 1, is nearly sinusoidal.

Sponsored Recommendations

Near- and Far-Field Measurements

April 16, 2024
In this comprehensive application note, we delve into the methods of measuring the transmission (or reception) pattern, a key determinant of antenna gain, using a vector network...

DigiKey Factory Tomorrow Season 3: Sustainable Manufacturing

April 16, 2024
Industry 4.0 is helping manufacturers develop and integrate technologies such as AI, edge computing and connectivity for the factories of tomorrow. Learn more at DigiKey today...

Connectivity – The Backbone of Sustainable Automation

April 16, 2024
Advanced interfaces for signals, data, and electrical power are essential. They help save resources and costs when networking production equipment.

Empowered by Cutting-Edge Automation Technology: The Sustainable Journey

April 16, 2024
Advanced automation is key to efficient production and is a powerful tool for optimizing infrastructure and processes in terms of sustainability.

Comments

To join the conversation, and become an exclusive member of Electronic Design, create an account today!