Understanding Common-Mode And Differential-Mode Interference

June 25, 2009
Brief refresher on terminology: differential versus common-mode.

When identifying and controlling electromagnetic interference (EMI), discussion of common-mode and differentialmode interference will likely dominate.

Differential-mode interference is a signal that appears on two lines of a closed loop, but current flow is in opposite directions. This kind of interference essentially appears in series with the desired signal. The solution is an inductor in series with the high side (and/or low side) of the line and a shunt capacitor across the lines.

A common-mode EMI signal appears on the two signal lines simultaneously in the same direction and phase. The signal on each line returns through a common ground. The solution, a common-mode choke, produces equal and opposite magnetic fields that cancel one another. A capacitor from each line to ground is also used.

Sponsored Recommendations

What are the Important Considerations when Assessing Cobot Safety?

April 16, 2024
A review of the requirements of ISO/TS 15066 and how they fit in with ISO 10218-1 and 10218-2 a consideration the complexities of collaboration.

Wire & Cable Cutting Digi-Spool® Service

April 16, 2024
Explore DigiKey’s Digi-Spool® professional cutting service for efficient and precise wire and cable management. Custom-cut to your exact specifications for a variety of cable ...

DigiKey Factory Tomorrow Season 3: Sustainable Manufacturing

April 16, 2024
Industry 4.0 is helping manufacturers develop and integrate technologies such as AI, edge computing and connectivity for the factories of tomorrow. Learn more at DigiKey today...

Connectivity – The Backbone of Sustainable Automation

April 16, 2024
Advanced interfaces for signals, data, and electrical power are essential. They help save resources and costs when networking production equipment.

Comments

To join the conversation, and become an exclusive member of Electronic Design, create an account today!